Choosing Gloves for Brake Cleaner and Solvents: How to Use SDS Section 8 in an Auto Shop

Walk through most repair shops and you will see the same thing: thin disposable gloves torn at the fingertips, or no gloves at all, while technicians spray brake cleaner and dip parts in solvent. Skin problems from solvents are among the most common occupational health issues for mechanics, and the fix starts with a section of the Safety Data Sheet that most people skip.

Quick answer: SDS Section 8, Exposure controls and personal protection, tells you what kind of hand protection a product requires. Use it to choose gloves made from a material that resists that chemical, then check the glove manufacturer's chemical resistance data for breakthrough time. OSHA requires a written hazard assessment for PPE under 29 CFR 1910.132(d), and hand protection under 1910.138, so document your choices and train technicians on them.

Disposable nitrile gloves are a good general-purpose choice for many shop tasks, but they are not right for every chemical or every exposure. This guide explains how to match gloves to products.

Table of contents

  • Why do glove choices matter?
  • What does SDS Section 8 tell you?
  • What do the glove standards require?
  • How do glove materials compare?
  • What is breakthrough time?
  • How do you build a glove chart for the shop?
  • What about skin care and hygiene?
  • How does Helios Comply help?
  • Frequently asked questions
  • Sources

Why do glove choices matter?

Solvents remove natural oils from skin, causing dryness, cracking, and irritant contact dermatitis. Some products contain ingredients that can cause allergic skin reactions. Some chemicals can pass through skin and add to the body's total exposure.

The wrong glove can make things worse. A glove that a solvent passes through quickly can trap the chemical against the skin, increasing exposure compared with a quick splash on bare skin.

What does SDS Section 8 tell you?

Section 8 typically includes:

  • Occupational exposure limits for hazardous ingredients
  • Engineering controls, such as ventilation
  • Eye and face protection
  • Skin protection, including glove material recommendations
  • Respiratory protection recommendations

Glove recommendations vary in quality. Some SDSs name a specific material, such as nitrile or Viton. Some say only "wear protective gloves." When the SDS is vague, use the composition in Section 3 to identify the main solvent, then check a glove manufacturer's chemical resistance guide.

What do the glove standards require?

OSHA's PPE standards require employers to:

  1. Assess hazards. Under 1910.132(d), assess the workplace to determine whether hazards are present that require PPE, and certify the assessment in writing with the workplace evaluated, the person certifying, and the date.
  2. Select appropriate PPE. Under 1910.138(b), base hand protection selection on an evaluation of performance characteristics relative to the tasks, conditions, duration of use, and hazards.
  3. Train employees. Under 1910.132(f), train employees on when PPE is necessary, what PPE is necessary, how to wear it, its limitations, and its care.

The SDS is the starting point for the hazard assessment. HazCom training should also cover protective measures, including PPE.

How do glove materials compare?

General tendencies are below. Always confirm with the glove manufacturer's data for the specific chemical.

Glove material Generally good for Generally poor for
Nitrile Oils, greases, many fuels, some aliphatic solvents, mild acids and bases Many ketones such as acetone; chlorinated solvents
Neoprene Acids, bases, some alcohols, some oils Some aromatic and chlorinated solvents
Butyl Ketones such as acetone, esters, many polar solvents Aliphatic and aromatic hydrocarbons such as gasoline and heptane
Viton (fluoroelastomer) Chlorinated and aromatic solvents Ketones; often costly
Natural rubber latex Water-based solutions, some acids and bases Most solvents and oils; latex allergy concerns
Laminate film Broad chemical resistance Dexterity; often worn under another glove

Brake cleaners show why this matters. A non-chlorinated cleaner based on acetone and heptane challenges nitrile from one direction and butyl from the other. A chlorinated cleaner may need a different material again. Thin disposable nitrile gloves can work for brief splash contact with some products, but should be changed immediately after contact.

What is breakthrough time?

Glove manufacturers test how long it takes a chemical to pass through the glove material. That is the breakthrough time. They may also report permeation rate and degradation ratings.

When reading a chemical resistance chart:

  • Check the specific chemical or the main solvent in the product.
  • Look at breakthrough time for the glove thickness you plan to use.
  • Thin disposable gloves often have short breakthrough times, sometimes only minutes.
  • Mixtures can behave differently from single chemicals.

Use breakthrough time to set rules. If a glove gives only a few minutes of protection, treat it as splash protection and change it after contact.

How do you build a glove chart for the shop?

Create a simple chart from your chemical inventory and SDSs:

Task or product group Main hazard Glove choice Change rule
General repair, oils, greases Skin irritation, dermatitis Disposable nitrile Change when torn or contaminated
Brake and parts cleaners Solvent penetration Per SDS and glove data Change immediately after splash
Parts washer, prolonged solvent contact Prolonged solvent exposure Heavier reusable gloves rated for the solvent Inspect before each use
Battery service, acids Corrosive Acid-resistant gloves, such as neoprene or butyl Inspect before each use
Paint mixing, isocyanates Sensitizer, solvents Per paint manufacturer's SDS Change per manufacturer guidance
Coolant draining Ingestion and skin contact Disposable nitrile Change when contaminated

Post the chart in the shop and include it in training. Put it in your PPE hazard assessment file.

What about skin care and hygiene?

Gloves are one part of preventing skin problems. Also:

  • Never wash hands with solvents or gasoline.
  • Provide hand-washing stations with suitable cleaners.
  • Wash before eating, drinking, or smoking.
  • Remove contaminated gloves without touching the outside.
  • Encourage technicians to report rashes, cracking, or itching early.

How does this fit into HazCom training?

HazCom training must include protective measures employees can take, including PPE. Teach technicians to open the SDS for a product, go to Section 8, and find the glove recommendation. Then show them the glove chart. For training formats that fit a busy shop, see how to train new employees on chemical hazards in under an hour.

How does Helios Comply help?

Helios Comply puts every SDS in your shop one QR scan away, so technicians can check Section 8 at the bay before picking up a product, including offline. A location-based library makes it easier to build glove charts by area, and the platform generates GHS labels for transferred products from the SDS.

The shop still owns its written program, training, and safety decisions. Start a free trial, call (855) 920-5202 for setup help, or compare SDS binder options.

This article provides general compliance information, not legal advice. Check applicable federal OSHA requirements and any state-plan requirements for your workplace.

Frequently asked questions

Are nitrile gloves good enough for brake cleaner?

Sometimes, for brief splash contact, but it depends on the formulation. Check the SDS and the glove manufacturer's chemical resistance data, and change gloves immediately after contact.

Does OSHA require a written PPE assessment?

Yes. Under 29 CFR 1910.132(d)(2), the employer must verify the hazard assessment through a written certification that identifies the workplace evaluated, the person certifying, and the date.

Who pays for gloves?

OSHA generally requires employers to pay for required PPE, with limited exceptions such as ordinary safety-toe footwear and prescription safety eyewear under certain conditions.

Sources

  • 29 CFR 1910.132, Personal Protective Equipment, General Requirements
  • 29 CFR 1910.138, Hand Protection
  • 29 CFR 1910.1200, Hazard Communication
  • NIOSH, Skin Exposures and Effects
×

    We'll Call You Within the Hour


    Fill in your details and a compliance expert will reach out to walk you through the platform.


    No sales pressure. We'll show you the platform and answer your questions.

    Scroll to Top

    Order Your SDS Book

    Fill in your details and we'll call you back within 30 minutes to complete your order.

      📞 We'll call you back within 30 minutes